Alert archive / North Carolina / Red Flag Warnings in 2008

Red Flag Warning 12, NWS Greenville-Spartanburg, SC

March 27, 200816 counties in North Carolina

NWS Greenville-Spartanburg, SC issued this red flag warning at Mar 27, 2008, 11:11 AM EDT for 16 counties in North Carolina. It took effect at Mar 27, 2008, 12:00 PM EDT. It was in force for 9 hr. No storm report in the archive falls inside the area while it was in force.

The area

The counties it named.

The facts

Issued
Mar 27, 2008, 11:11 AM EDT (15:11 UTC)
In effect from
Mar 27, 2008, 12:00 PM EDT
Expired
Mar 27, 2008, 9:00 PM EDT
In force
9 hr
Issued by
NWS Greenville-Spartanburg, SC

Counties Alexander County, NC, Burke County, NC, Cabarrus County, NC, Caldwell County, NC, Catawba County, NC, Cleveland County, NC, Davie County, NC, Gaston County, NC, Iredell County, NC, Lincoln County, NC, McDowell County, NC, Mecklenburg County, NC, Polk County, NC, Rowan County, NC, Rutherford County, NC, Union County, NC

The radar

The Greer radar (KGSP), 117 km from the middle of the area, began a volume at 15:14 UTC, the scan nearest the moment this went out.

Open the radar archive at this moment

The archived warnings, watches and discussions in force at that minute are drawn over the scan, this one among them.

The nearest sounding before it

Greensboro/Hi Pt, NC (KGSO), launched 12:00Z, 3.2 hours before the alert went out and 133 km from the middle of its area. This is the routine balloon launch nearest before it, the air the forecaster had in hand, not a measurement taken for the alert.

Skew-T log-pSkew-T log-p diagram, Greensboro/Hi Pt, NC at 12:00Z on 2008-03-27Temperature and dew point through the depth of the atmosphere, with the mixed-layer parcel. CAPE 0 joules per kilogram.LCL10008507005003002001001 km2 km3 km6 km9 km12 km15 km-30°-20°-10°0°10°20°30°40°
Temperature in red, dew point in green, the mixed-layer parcel dashed.
HodographHodograph, Greensboro/Hi Pt, NC at 12:00Z on 2008-03-27The wind through the lowest 10 kilometers. Zero to 1 km storm-relative helicity 41 square meters per square second.19395878Sfc1 km3 km6 km9 kmRMLM
The wind turning with height, colored by layer: ground to 1 km, 1 to 3 km, 3 to 6 km, 6 to 10 km.
Mixed-layer CAPE
0 J/kg
Mixed-layer CIN
No buoyant parcel
Mixed-layer LCL
2152 m above ground
0-6 km bulk shear
33 kt
0-1 km storm-relative helicity
41 m²/s²
0-3 km storm-relative helicity
90 m²/s²
Significant tornado parameter
0.0
Supercell composite
0.0

Open this sounding in Storm Lab

Nearby

Red Flag Warnings in North Carolina, 2008Every red flag warning in 2008

Sources

The product and its follow-ups from the Iowa Environmental Mesonet's archive of National Weather Service and Storm Prediction Center text; the sounding from the Mesonet's radiosonde archive; radar from the NEXRAD Level II archive.